AOI US Closed

Barcode fail input options

CustomerNot indexed
CompanyNot indexed
Priority2
TypeAOI - No Action Required
UpdatedMay 11, 2026 at 12:25 PM
Thread2 messages

Current case

Customer issue

Good morning, We're having issues with our labels during inspection and some of the are failing. I have the Line stop setting enabled whenever barcodes fail so they enter them manually in those cases and while the machines whenever any barcode fails, it sometimes doesn't show the virtual keyboard so they can enter the serial number. I suspect it is only showing the keyboard to enter the serial whenever a PCBID label fails but not for the BlockID labels. Is this normal? Is there a different setting that should be on for BlockID labels? R, Luis A Reyes Aviles | LSSGB | Manufacturing Engineer -------------------------- Sypris Electronics, LLC 10421 University Center Drive Tampa, FL 33612 [email] | [phone] Trust Beyond Manufacturing(r) [email] ________________________________ NOTICE The information contained in this communication may be sensitive, proprietary, legally privileged and/or subject to U.S. export laws. It is intended only for the use of the recipient named above. Your opening of this email is a tacit agreement to comply strictly with all U.S. export laws and assume sole responsibility for obtaining licenses to export or re-export as may be required. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication, or any of its contents, is strictly prohibited. If you have received this communication in error, please re-send this communication to the sender and delete the original message and any copy of it.

Conversation

Engineer and customer thread

2 messages
  1. Omron Application Engineer Omron reply | Apr 17, 2026 at 1:40 PM
    Hello Luis, ​ From what you described, it looks like the system behavior may be slightly different between PCBID and BlockID when a barcode read fails. Specifically, the on-screen keyboard may not automatically appear in all cases, even though manual input is still allowed. To help confirm this, could you please try the following quick test: On the AOI PC, press Windows + R Type osk and press Enter (this will open the Windows on-screen keyboard) Leave the keyboard open Run inspection and allow a BlockID barcode to fail Try manually entering the value using the on-screen keyboard If the system accepts the input, this would indicate that manual entry is still functioning, and the difference is only that the keyboard is not automatically popping up for BlockID in the same way it does for PCBID. As a workaround, you can also pin the on-screen keyboard to the taskbar so operators can easily open it when needed. Please let us know the results of this test, and we can advise further based on what you observe. Best regards,
  2. Omron Application Engineer Omron reply | May 1, 2026 at 10:23 AM
    No sanitized conversation text indexed.