[Support Request] Error on Omron AOI Equipment - Assistance Required
CustomerJustin Kim
CompanyNot indexed
Priority2
TypeAOI - No Action Required
UpdatedAug 21, 2026 at 10:02 AM
Thread5 messages
Ticket metadata
Group
AOI US (150000419797)
Status
Closed (5)
Created
Aug 10, 2026 at 11:46 AM
Requester
Justin Kim <justin.kim@creationtech.com>
Company
Not indexed
Last synced
Aug 21, 2026 at 10:15 AM
Resolved
Aug 10, 2026 at 8:48 PM
Closed
Aug 19, 2026 at 12:22 AM
Tags
A - AOI CASE ACK EN, A - Reply Open, A - 1 Hour Delay rslv, AOI - New CSAT Sent, LOCKED, AOI - New CSAT Received
Current case
Customer issue
Hi Support team, We are experiencing an error on the Omron AOI equipment, as shown in the attached image. We have tried restarting both the software and the machine's power, but the issue still persists. For your reference, we have captured the TeamViewer session below. Could you please help me resolve this issue? My personal number is [phone]. Best Regards, Justin Kim Equipment Maintenance - Technician Creation Technologies Office: [phone] x 3408 8999 Fraserton Court | Burnaby, BC V5J 5H8 | Canada [email] | www.creationtech.com
Conversation
Engineer and customer thread
5 messages
JS
Jeremiah SolizOmron reply | Aug 10, 2026 at 12:18 PM
Hello Justin, The problem has been resolved, can you please login and test?
JS
Jeremiah SolizPrivate note | Aug 10, 2026 at 12:20 PM
Private
Resolved S730 ImageSensorControlFailedInitialize error (0x02903006). Compared the current Configuration folder against Configuration_old and found several camera/grabber configuration files missing from the active Configuration\Hardware directory. HardwareConfiguration.xml was still referencing these files. Copied the following files from Configuration_old\Hardware into Configuration\Hardware: S720_F760K_8bit_Trigger.dcf STC-GEC152A.dcf STC-CMB401PCL.ini After restoring these files, the machine was able to initialize normally and the image sensor/grabber error was resolved.
C
CustomerCustomer reply | Aug 10, 2026 at 12:30 PM
Thank you. I have logged in, and we will conduct the test once the operator arrives. I will contact you if any issues occur during the test. Best Regards, Justin Kim Equipment Maintenance - Technician Creation Technologies Office: [phone] x 3408 8999 Fraserton Court | Burnaby, BC V5J 5H8 | Canada [email] | www.creationtech.com ________________________________
freshdesk-inline-150173491708.png
OA
Omron Application EngineerOmron reply | Aug 10, 2026 at 10:23 PM