A - AOI CASE ACK EN, A - Reply Open, A - 1 Hour Delay rslv, LOCKED
Current case
Customer issue
Good morning, I see this issue at times with parts being called for component tilt. When I check on them via v-TS I see the following: [cid:d62caa64-711c-47f2-8961-cc2d5341330d] How does the AOI end up with what appears to be missing data? Thanks in advance for your asisstance. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com [cid:bd8394ee-0e4a-4aa5-89ff-9c7c7a4c8e21]
Conversation
Engineer and customer thread
12 messages
OA
Omron Application EngineerOmron reply | Oct 24, 2025 at 10:46 AM
Hello George, Is there any tall component around this chip resistor? When was the last time you guys run machine calibration with the plate?
OA
Omron Application EngineerOmron reply | Nov 3, 2025 at 7:24 AM
Hello George, Is there any update on this ticket?
C
CustomerCustomer reply | Nov 3, 2025 at 9:39 AM
Good morning, apologies for not following up sooner on this. For this example, I consistently see it here. [cid:8ee1b20f-a7ff-4633-ac8f-7be6b3647844] While I'm on this board in particular, these resistors below often have difficulty and are usually flagged as wrong component. They are wedged between some decent sized caps. [cid:d4310dd0-27bb-406e-9d41-36bc5c59aa5b] With regards to calibration, I do not have a specific date but it was done within the last 30-45 days. I could give you a definitive answer if I knew where to locate the results. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com [cid:a08dc5f0-3b80-46e3-93ba-97f7c800a82d] ________________________________
OA
Omron Application EngineerOmron reply | Nov 3, 2025 at 5:27 PM
Hello George, There appears to be an issue with your component 3D profiling. Can you please run the 3D calibration/validation plate and provide results Thanks,
freshdesk-inline-150136756760.png
C
CustomerCustomer reply | Nov 3, 2025 at 5:28 PM
Thanks, will do and report back on this. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com [cid:a16e2696-065f-4226-9566-f065fe098ed1] ________________________________
freshdesk-inline-150136756876.png
OA
Omron Application EngineerOmron reply | Nov 4, 2025 at 8:03 PM
Hello George, Could you try enabling Secondary reflection for those components, it may be difficult to perfectly reconstruct those components because S730 does not have our latest technology called MPS but you can try.
OI
Omron internalPrivate note | Nov 5, 2025 at 1:29 PM
Private
Tickets with IDs 1630276 is merged into this ticket.
OI
Omron internalPrivate note | Nov 5, 2025 at 1:29 PM
Private
Merged from ticket 1630276 Subject: Re: [EXT] Re: Missing data in component tilt [Case: 1622106] Description: Here's some examples from a different board, there's no large or tall components around thees. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com From: George Ottesen Sent: Monday, November 3, 2025 7:39 AM To: AOI Tech Support - US Cc: Darren Otterwell Subject: Re: [EXT] Re: Missing data in component tilt [Case: 1622106] Good morning, apologies for not following up sooner on this. For this example, I consistently see it here. While I'm on this board in particular, these resistors below often have difficulty and are usually flagged as wrong component. They are wedged between some decent sized caps. With regards to calibration, I do not have a specific date but it was done within the last 30-45 days. I could give you a definitive answer if I knew where to locate the results. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com From: AOI Tech Support - US Sent: Monday, November 3, 2025 5:24 AM To: George Ottesen Cc: Darren Otterwell Subject: [EXT] Re: Missing data in component tilt [Case: 1622106] This email originated from outside of Creation. Do not click links or open attachments unless you recognize the sender AND are expecting the message. Hello George, Is there any update on this ticket? On Fri, 24 Oct at 9:46 AM , AOI Product Group wrote: Hello George, Is there any tall component around this chip resistor? When was the last time you guys run machine calibration with the plate? On Thu, 23 Oct at 12:21 PM , George Ottesen wrote: Good morning, I see this issue at times with parts being called for component tilt. When I check on them via v-TS I see the following: How does the AOI end up with what appears to be missing data? Thanks in advance for your asisstance. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com 1622106:2549832
Omron Application EngineerOmron reply | Nov 6, 2025 at 1:34 PM
Hello George, I have some question: Is there any cooling conveyor between the reflow oven and the AOI? What the temperature of the boards when they going in to the machine? When you open the front door and touch the illumination unit does it is sticky? Does this happen only this this particular component or all of them on the same board?
C
CustomerCustomer reply | Nov 6, 2025 at 2:24 PM
Hello, There is approximately 5' of conveyor between the oven and AOI. I do not know the exact temp of the PCB. After enabling the secondary reflection, the calls for these have improved greatly. George Ottesen Process Engineering Technician Creation Technologies Cell: [phone] 1450 Mission Ave NE | Albuquerque, NM 87107 | USA [email] | www.creationtech.com [cid:7ddb94fc-5da4-4a72-8cc7-30e2c4d8800a] ________________________________
Omron Application EngineerOmron reply | Nov 10, 2025 at 8:56 AM
Hello George, Thanks for the update. I asked about the conveyors because we’ve noticed cases where the machine is positioned too close to the oven. When the PCB enters the machine, its temperature is still high, causing flux condensation inside the equipment. Over time, this leads to lens contamination
OI
Omron internalPrivate note | Nov 10, 2025 at 9:30 AM
Private
Subject: RE: Missing data in component tilt [ AOI Case# 1622106] has been resolved. Description: Hello George, Thank you for your recent inquiry. We’re pleased to inform you that your case 1622106 has been resolved. As always, we're here to support you. If you need assistance in the future, please don’t hesitate to reach out to us via our support email: [email] If you believe further support is needed regarding this case, simply reply to this message with a brief status update, and we’ll be happy to assist you. Francisco Javier Villalpando Your Omron AOI Technical Support Group