A - AOI CASE ACK EN, A - Reply Open, A - 1 Hour Delay rslv, AOI - New CSAT Sent, LOCKED
Current case
Customer issue
Ok the machine works, however the Main Menu on the machine software never comes up. If you hit the "start" button on the machine you can enter the password and then wait a little bit and when you hit it again the program load screen comes up. But the main software screen never shows on the screen. Also, I figured out why you never got an email from [email] . There was no "c" on com. Ray Partenheimer Director of Engineering [email] SMTC Corporation 425 North Drive Melbourne, FL 32934 Work Cell: [phone] E-mail: [email] Web: www.mcati.com www.smtc.com From: Ray Partenheimer Sent: Monday, July 13, 2026 5:46 PM To: [email] James Cavanaugh ; Quang Cung ; [email] Cc: Juan Salinas ; Ronald Pomerleau ; Khi Singleton ; Renford Henry Subject: Re: [EXTERNAL EMAIL] Re: error message Hi Ryan, We have tried the above. Right now I launch the software and it looks like it is coming up alright. But the software never comes up (see the attached photo). Is there anything else we can look at? Sent from my Verizon, Samsung Galaxy smartphone Get Outlook for Android ________________________________ From: [email] > Sent: Friday, 10 July 2026 15:53:57 To: James Cavanaugh >; Quang Cung >; [email] > Cc: Ray Partenheimer >; Juan Salinas >; Ronald Pomerleau >; Khi Singleton >; Renford Henry > Subject: Re: [EXTERNAL EMAIL] Re: error message FYI the process would be called "last committed" Get Outlook for iOS ________________________________ From: James Cavanaugh > Sent: Friday, 10 July 2026 14:51:50 To: Ryan Morrow / OEI >; Quang Cung >; [email] > Cc: Ray Partenheimer >; Juan Salinas >; Ronald Pomerleau >; Khi Singleton >; Renford Henry > Subject: RE: [EXTERNAL EMAIL] Re: error message There shouldn't be any issues with RW privileges. @Quang Cung you can reboot the xray computer to ensure the application isn't hung and still running a process in the background. James Cavanaugh System Administrator SMTC Corporation From: [email] > Sent: Friday, July 10, 2026 3:50 PM To: Quang Cung >; [email] Cc: Ray Partenheimer >; Juan Salinas >; Ronald Pomerleau >; James Cavanaugh >; Khi Singleton >; Renford Henry > Subject: Re: [EXTERNAL EMAIL] Re: error message The entire Omron folder needs full RW privileges for admin and user (if that is what is logged in). Also make sure that the main software is closed. Get Outlook for iOS ________________________________ From: Quang Cung > Sent: Friday, 10 July 2026 14:36:32 To: [email] > Cc: Ray Partenheimer >; Juan Salinas >; Ryan Morrow / OEI >; Ronald Pomerleau >; James Cavanaugh >; Khi Singleton >; Renford Henry > Subject: RE: [EXTERNAL EMAIL] Re: error message You don't often get email from [email] . Learn why this is important Hello Omron support team I try the instruction below with admin account and still didn't let me rename the file. I have copy IT team. [email] Please advise! Thanks Quang Cung From: [email] > Sent: Friday, July 10, 2026 7:56 AM To: Quang Cung > Cc: Ray Partenheimer >; Juan Salinas > Subject: [EXTERNAL EMAIL] Re: error message EXTERNAL EMAIL: This message originated from outside your organization. Do not click any links or open any attachments unless you trust and know the content is safe. Normally this error message occurs after a power outage that cause one of the .ini file to become corrupted. Get back to desktop, ensure the Omron software is properly closed, navigate to c:/Program Files/Omron/VT-X750/config looks for file called "NWIN.ini" rename this to "old_NWiN.ini" then find NWIN.BAK make a copy of it, then rename the copy to "NWIN.ini". Close windows, after a few minute power cycle the main power breaker switch on back door, leave off for 1 minute, then turn switch back to on, start like you normally would. If pretty sure this will fix it but if not, please reach out AOIsupport email. I'll be at a facility this morning where I'm not permitted to bring any electronic device in so I will not be able to communicate further to help. Get Outlook for iOS ________________________________ From: Quang Cung > Sent: Thursday, 09 July 2026 21:44:51 To: Ryan Morrow / OEI > Cc: Ray Partenheimer >; Juan Salinas > Subject: error message You don't often get email from [email] . Learn why this is important Hello Ryan I got this error message; I do not know what was wrong. How do I reset or clear it? Thanks [email] Quang Cung Process Engineer SMTC-Melbourne,Fl [email] ________________________________ PROPRIETARY INFORMATION NOTICE: This email and its attachments may contain material that is confidential, privileged and/or for the sole use of the intended recipient. Any review, reliance or distribution by others or forwarding without express permission is strictly prohibited. If you are not the intended recipient, you may not copy, forward, use, rely on or distribute this message or any file attachments. Please inform the sender if you have received this email in error. Nothing in this email amounts to a contractual or other legal commitment, unless separately confirmed expressly in writing by an authorized Officer of the Company. The views expressed in this email are attributable to the sender and may not necessarily reflect the views of the Company. WARNING: This document may contain technical data whose export is restricted by the International Traffic in Arms Regulations (22 CFR Part 120 et seq.) or the Export Administration Regulations (15 CFR Part 730 et seq.). Disseminate in accordance with provisions of DoD Directive 5230.25. Disclosure to foreign persons without prior U.S. Government approval is prohibited. Violations of these export laws and regulations are subject to severe civil and criminal penalties. This transmittal may contain company confidential, proprietary and/or information regulated by the International Traffic in Arms Regulations (ITAR) and may be subject to U.S. Government Export Control Laws. This information is intended for use only by the recipient. Transfer of this information to any foreign party, whether in the U.S. or abroad, without Department of State approval and/or licensing is prohibited. GUID: f41d0b20-f277-4b1e-9c53-1bed7e9bb8a0 WARNING! This is an email from an external party. Do not click on any link or open any attachment if you cannot ascertain that it is safe. WARNING! This is an email from an external party. Do not click on any link or open any attachment if you cannot ascertain that it is safe. WARNING! This is an email from an external party. Do not click on any link or open any attachment if you cannot ascertain that it is safe.
Hello Ray, To display the main menu again, follow these steps: Close the main software by holding the Shift key while clicking Shut Down. Keep holding the Shift key until the software is completely closed, then release it. Go to: C:\Program Files\OMRON\VT-X750\Config Open the HISTORY.ini file. Locate the Machine_form setting and change it to the value shown below. Save the changes. Launch the software again. [MAIN_FORM] MAIN_FORM_POS_X=0 MAIN_FORM_POS_Y=0 Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
OI
Omron internalPrivate note | Jul 13, 2026 at 6:45 PM
Private
Merged from ticket 1812107 Subject: X750 Issue Description: Hi Doug Max informed me that your X750 machine has been down since the power outage last Friday. Could you please provide additional details about the issue, including any error messages or screenshots? If possible, please also provide TeamViewer access so we can investigate remotely. Please be aware that this is our official support channel. For a faster response, please send future support requests directly to this email. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
OI
Omron internalPrivate note | Jul 13, 2026 at 6:45 PM
Private
Tickets with IDs 1812107 is merged into this ticket.
C
CustomerCustomer reply | Jul 14, 2026 at 7:29 AM
Thank you. The machine is now running. Thank you for your help. Ray Partenheimer Director of Engineering [email] SMTC Corporation 425 North Drive Melbourne, FL 32934 Work Cell: [phone] E-mail: [email] Web: www.mcati.com www.smtc.com
attachmentattachment
2 tiny or repeated images hidden.
OA
Omron Application EngineerOmron reply | Jul 14, 2026 at 10:26 AM