A - AOI CASE ACK SP, A - Reply Open, A - 1 Hour Delay rslv, AOI - New CSAT Sent, LOCKED
Current case
Customer issue
Las IP coinciden en la maquina con lo que tenemos en el vDBtool [cid:71dfbcfb-47db-4610-8ce6-411177abd167] Best Regards AP ________________________________ From: AOI Tech Support - MX Sent: Friday, July 17, 2026 8:51 AM To: Antonio Posada Subject: Re: Power Off Constante [Case: 1803142] CAUTION: External Email. Please be aware and alert. Buen día Antonio Hemos visto ese error cuando hay diferencias en las IP Address. Puedes verificar que la IP Address de la maquina coincida con la IP address declarada para esa maquina en el vDBtool? Saludos Claudio E. [X] Claudio Echeverría OMX-OEI AOI Engineer Supervisor Direct: +52 55.3939.5699 | [email] Omron Mexico Niba Corporate Tower | Av. de las Américas 1462, 8th Floor | Country Club | Guadalajara, Jalisco 44610, Mexico automation.omron.com [X] [X] [X] [X] This is a confidential message. If received in error, delete it and notify the sender. Activado Vie, 3 Jul a 10:17 A. M. , Antonio Posada escribió: Hola Juan Aun no se resuelve, el problema es que no esta corriendo por el momento la linea. Esta es la imagen del error. El problema es que no me permite hacer un recovery del error. Esto paso aproximadamente 6 veces en un dia [https://attachment.freshdesk.com/inline/attachment?token=eyJ0eXAiOiJKV1QiLCJhbGciOiJIUzI1NiJ9.eyJpZCI6MTUwMTY4NDg2NTY5LCJkb21haW4iOiJvbXJvbmVsZWN0cm9uaWNzbGxjLmZyZXNoZGVzay5jb20iLCJhY2NvdW50X2lkIjoyNTQ5ODMyfQ.8lIBIPk2LBLihpSj5R4ZYwY-2MjgtI6uFdTTJieC0wE] Best Regards AP ________________________________ From: AOI Tech Support - MX Sent: Thursday, July 2, 2026 5:31 PM To: Antonio Posada Subject: Re: Power Off Constante [Case: 1803142] CAUTION: External Email. Please be aware and alert. Hola Antonio, Ya pudieron resolver el problema? ese error se refiere a conexion a base de datos el equipo no tiene acceso a ala base o ala red. Juan Lazcano Application Engineer Inspection System Direct: +52 [phone] | [email] Omron Mexico Niba Corporate Tower | Av. de las Américas 1462, 8th Floor | Country Club | Guadalajara, Jalisco 44610, Mexico automation.omron.com This is a confidential message. If received in error, delete it and notify the sender. Activado Mar, 30 Jun a 5:37 P. M. , AOI Tech Support - MX escribió: Hola Antonio, ¿tendrás alguna imagen del error? en los logs aparecen errores de conexion, de transferencia. Best Regards [https://outlook.office.com/mail/inbox/id/AAkALgAAAAAAHYQDEapmEc2byACqAC%2FEWg0A0upKdiazWke6N55pIJBZIQABTH1wzgAA?nativeVersion=1.2026.623.400] Rubén Domínguez Application Engineer Inspection System Direct: +52 33.1410.8053 | [email] Omron Mexico Blvd. Miguel de Cervantes Saavedra 169, 1st Floor | Granada | Miguel Hidalgo | Mexico City, CDMX 11520, Mexico automation.omron.com This is a confidential message. If received in error, delete it and notify the sender. Activado Mar, 30 Jun a 1:42 P. M. , Antonio Posada escribió: Buen dia, Me pueden apoyar con una AOI que me marca un error constante terminacion 0006. Que solo permite reiniciar la maquina, no deja reiniciar ni nada. Adjunto los logs del equipo Best regards / Saludos [https://outlook.office.com/mail/inbox/id/AAkALgAAAAAAHYQDEapmEc2byACqAC%2FEWg0A0upKdiazWke6N55pIJBZIQABTH1wzgAA?nativeVersion=1.2026.623.400] Antonio Posada Test Engineer Volex Inc Tijuana, B.C. [www.volex.com] Antonio Posada Test Engineer Volex de Mexico Av 32 Sur, No. 8950, Tijuana, Baja California, 22116 t:+52 [phone] | m: | f: [email] w: www.volex.com This email and its attachments contain confidential and/or legally privileged information, intended only for the named recipient(s). If you have received this email in error, please notify the sender immediately, delete it, and do not read, copy, or distribute its contents. The contents of this email may be subject to applicable export control laws and regulations. It is the recipient's responsibility to ensure that any onward transmission, disclosure, or use complies with such laws and that information is not shared without appropriate authorization. The Volex group complies with all relevant global import and export control laws and regulations. Volex group companies are located worldwide, including the UK, US, EU, China, Mexico, Türkiye, India, Vietnam, and Indonesia. Accordingly, potential or current customers and suppliers should exercise care when sending export-controlled information to any Volex entity or employee by ensuring the release of such information is authorized. Information subject to U.S. export controls under the EAR, ITAR, or other such regulations should not be provided to U.S. entities within the Volex group unless it has been expressly authorized to be exported to the recipient by the cognizant U.S. regulatory body via a license or license exception/exemption Nothing in this email or any attachments shall be construed as a legally binding offer, acceptance, or agreement unless explicitly stated otherwise in a separate written agreement. All email communications are subject to contract. Volex accepts no liability for any damage caused by any virus transmitted by this email. 1803142:2549832 1803142:2549832
Conversation
Engineer and customer thread
7 messages
JL
Juan LazcanoOmron reply | Jul 23, 2026 at 12:46 PM
Hola Antonio, Ese error normalmente es por la red, desde que se instalaron las maquinas hay intermitencia en la red. hay una aplicacion en el escritorio de la maquina que se llama machine monitor, ahi puedes monitorear la red para que veas los picos o los cortes que hace la red, te muestro una pantalla de ejemplo, esto se puede deber al tipo de cable, o algun daño en el cable, ahi se pudo un sw junto al server para la conexion que desde que se instalaron las maquinas dio algunas intermitencias Juan Lazcano Application Engineer Inspection System Direct: +52 [phone] | [email] Omron Mexico Niba Corporate Tower | Av. de las Américas 1462, 8th Floor | Country Club | Guadalajara, Jalisco 44610, Mexico automation.omron.com This is a confidential message. If received in error, delete it and notify the sender.
C
CustomerCustomer reply | Jul 23, 2026 at 5:12 PM
Hola Juan Oye encontre esta discrepancia en el Machine Monitor. La IP configurada en la tarjeta del equipo no corresponde con la que aparece en el MachineMonitor Local IP debe ser 192.168.0.104 [cid:e778c0c9-1a42-4393-bc62-ce8a0a32addd] Best Regards AP ________________________________
JL
Juan LazcanoOmron reply | Jul 23, 2026 at 5:45 PM
Hola Antonio, Las maquinas tienen dos puertos de red puedes revisar el segundo puerto tal vez ahi esta asignado la ip. hay uno asignado al PLC y no se debe cambiar Juan Lazcano Application Engineer Inspection System Direct: +52 [phone] | [email] Omron Mexico Niba Corporate Tower | Av. de las Américas 1462, 8th Floor | Country Club | Guadalajara, Jalisco 44610, Mexico automation.omron.com This is a confidential message. If received in error, delete it and notify the sender.
C
CustomerCustomer reply | Jul 23, 2026 at 6:10 PM
Las IP del PLC no se han cambiado Solo las de la tarjeta de entrada de red. AOI S730 [cid:f0e1f52b-3aaf-405d-8ce5-30763a1d7563] AOI S530 [cid:88e11d6b-a15e-431b-81b4-e88030c0ed16] Best Regards AP ________________________________
Hola Antonio, Esas maquinas son de linea 1 la 103 es para la S530 y la 104 es para la S730. Si haces ping al server desde esas maquinas si lo hace? y entre ellas tambien? si haces pin largo lo hace? constante sin picos? tambien puedes saturar la red, al ser una red local no debe tener problemas a solo que el cableado este mal ping 192.168.0.id del server -l 400000 -t debe darte maximo 3seg de respuesta Juan Lazcano Application Engineer Inspection System Direct: +52 [phone] | [email] Omron Mexico Niba Corporate Tower | Av. de las Américas 1462, 8th Floor | Country Club | Guadalajara, Jalisco 44610, Mexico automation.omron.com This is a confidential message. If received in error, delete it and notify the sender.
RD
Ruben DominguezOmron reply | Jul 28, 2026 at 10:21 AM
Hola Antonio, ¿Se ha solucionado el problema o continúa experimentando la incidencia? Best Regards Rubén Domínguez Application Engineer Inspection System Direct: +52 33.1410.8053 | [email] automation.omron.com This is a confidential message. If received in error, delete it and notify the sender.