A - AOI CASE ACK EN, A - Reply Open, COLAB RUN, A - CN RUN, A - 1 Hour Delay rslv, AOI - New CSAT Sent, LOCKED
Current case
Customer issue
Hello Team, Could you please assist with this error. Thank you, Tanush Harish Bhaskar | Senior Engineer HUGHES | 19710 Observation Ln, Germantown, MD 20876 [email] | [phone]
Conversation
Engineer and customer thread
12 messages
FV
Francisco VillalpandoOmron reply | Jul 24, 2026 at 10:30 AM
Hello Tanush, Could you please collect all the log files from today and send it to us. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
C
CustomerCustomer reply | Jul 24, 2026 at 10:36 AM
Fransico, Where I get the log files from. Thank you, Tanush Harish Bhaskar | Senior Engineer HUGHES | 19710 Observation Ln, Germantown, MD 20876 [email] | [phone] ________________________________
FV
Francisco VillalpandoOmron reply | Jul 24, 2026 at 11:10 AM
Hello Tanush, C:\Program Files\OMRON\CTS-X_750\Log, sort by day and send us all the ,txt and .log files. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
C
CustomerCustomer reply | Jul 29, 2026 at 10:19 AM
Fransico, I have sent the files through we transfer. Thank you, Tanush Harish Bhaskar | Senior Engineer HUGHES | 19710 Observation Ln, Germantown, MD 20876 [email] | [phone] ________________________________
Francisco VillalpandoOmron reply | Jul 29, 2026 at 2:36 PM
Hello Tanush, I was not able to find any email from you or WeTransfer, could you upload logs to this link? https://app.box.com/s/whnr94k61taaww1g4vvkdbejq467pqm5 Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
FV
Francisco VillalpandoOmron reply | Jul 29, 2026 at 3:16 PM
Hello Tanush, After reviewing the logs, the issue appears to be related to the X-ray source. The following entry shows that the source has accumulated 20,599 power-on hours: [2026/07/16 08:16:55] [INFORMATION] Operation log in X-ray source: Power supply on time [20599 h] This X-ray tube was installed on July 25, 2023, so it has been in service for three years. Based on its current operating hours and age, the X-ray source should be replaced. As you may recall, the service life of the Canon X-ray source is based on total power-supply-on time. This means the operating-hour counter continues to increase whenever the machine is powered on, even when it is not inspecting products. This differs from Hamamatsu X-ray sources, whose service life is primarily based on actual radiation time. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email]
C
CustomerCustomer reply | Jul 29, 2026 at 3:18 PM
Fransico, Could you please send me a quote immediately. Thank you, Tanush Harish Bhaskar | Senior Engineer HUGHES | 19710 Observation Ln, Germantown, MD 20876 [email] | [phone] ________________________________
C
CustomerCustomer reply | Jul 29, 2026 at 4:13 PM
Private
Hi Tanush, Working on it. You’ll have it shortly. [This is Max Fabiano's card. Their email is [email] Their phone number is +[phone].]
freshdesk-inline-150171988177.png
C
CustomerCustomer reply | Jul 29, 2026 at 4:29 PM
Private
Tanush, Please see quote attached. One unit is in stock. Thank you, [This is Max Fabiano's card. Their email is [email] Their phone number is +[phone].]
freshdesk-inline-150171990777.png
OI
Omron internalPrivate note | Jul 29, 2026 at 4:37 PM
Private
COLAB NOTE UPDATE This case has received a Note from a Collaborator and has been TAG and Possibly Reopened. Please verify if any further action is required.
OA
Omron Application EngineerOmron reply | Aug 5, 2026 at 4:25 PM