[Support Request] Error on Omron AOI Equipment - Assistance Required
CustomerJustin Kim
CompanyNot indexed
Priority2
TypeN/A
UpdatedAug 21, 2026 at 5:47 PM
Thread1 messages
Ticket metadata
Group
AOI US (150000419797)
Status
Waiting for Customer (6)
Created
Aug 21, 2026 at 5:25 PM
Requester
Justin Kim <justin.kim@creationtech.com>
Company
Not indexed
Last synced
Aug 21, 2026 at 6:02 PM
Resolved
N/A
Closed
N/A
Tags
A - AOI CASE ACK EN
Current case
Customer issue
Hi Support team, We are experiencing an error on the Omron AOI equipment, as shown in the attached image. The PCB has stopped and an alarm is triggering. For your reference, we have captured the TeamViewer session below. Could you please help me resolve this issue? My personal number is [phone]. Best Regards, Justin Kim Equipment Maintenance - Technician Creation Technologies Office: [phone] x 3408 8999 Fraserton Court | Burnaby, BC V5J 5H8 | Canada [email] | www.creationtech.com
Conversation
Engineer and customer thread
1 messages
FV
Francisco VillalpandoOmron reply | Aug 21, 2026 at 5:47 PM
Hello Justin, Error code 0x02835002 indicates that, during PCB loading, the deceleration sensor detects the PCB before the loading sensor. Please clean the fiber sensors on the conveyor and check the conveyor belts for any fraying or damage that could interfere with PCB movement or sensor detection. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email] (Non-ITAR)