AOI US Waiting for Customer

[Support Request] Error on Omron AOI Equipment - Assistance Required

CustomerJustin Kim
CompanyNot indexed
Priority2
TypeN/A
UpdatedAug 21, 2026 at 5:47 PM
Thread1 messages

Current case

Customer issue

Hi Support team, We are experiencing an error on the Omron AOI equipment, as shown in the attached image. The PCB has stopped and an alarm is triggering. For your reference, we have captured the TeamViewer session below. Could you please help me resolve this issue? My personal number is [phone]. Best Regards, Justin Kim Equipment Maintenance - Technician Creation Technologies Office: [phone] x 3408 8999 Fraserton Court | Burnaby, BC V5J 5H8 | Canada [email] | www.creationtech.com

Conversation

Engineer and customer thread

1 messages
  1. Francisco Villalpando Omron reply | Aug 21, 2026 at 5:47 PM
    Hello Justin, Error code 0x02835002 indicates that, during PCB loading, the deceleration sensor detects the PCB before the loading sensor. Please clean the fiber sensors on the conveyor and check the conveyor belts for any fraying or damage that could interfere with PCB movement or sensor detection. Francisco Villalpando Engineering Supervisor Direct: +[phone] [email] (Non-ITAR)