A - AOI CASE ACK EN, A - Reply Open, A - 1 Hour Delay rslv, AOI - New CSAT Sent, LOCKED
Current case
Customer issue
Good morning, One of our SPI machines is not connecting to QUP Navi and when I checked in with my operators on our other production line, they said they had no issues, but I'd like for someone to remote into our system and check both machines out. The error message we're getting is "Not connected to network with Q-up Navi. It inspects without a data output as a result of Q-up Navi.". And then gives us an option of Yes or No. I went to our Q-Up Navi server(192.168.70.19) and was able to ping the machine (192.168.70.247). I was able to ping the server from the machine as well. We recently experienced some IT issues which according to our IT company those should be resolved, so I'd appreciate some assistance in getting our machines back up and running or at least a diagnostic answer that I can go back to our IT company with. TeamViewer login: 1 294 436 492 TeamViewer Pass: exuytz3a Sincerely, [email] Michael Tufts SMT Manager Mobile [phone] Email [email] Web www.bgmeng.com Engineering / Manufacturing 14100 Simone Drive Shelby Twp., MI 48315 WARNING: The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination, or other use of, or taking any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer. This communication could contain technical data whose export is restricted by the Arms Export Control Act (Tile 22, U.S.C., 22401 et seq.) and the International Traffic and Arms Regulations. Such technical data may not be disclosed to foreign persons or otherwise exported without obtaining required U.S. Government export authorization. Violations of these export laws are subject to severe criminal penalties.
Conversation
Engineer and customer thread
7 messages
OA
Omron Application EngineerOmron reply | Apr 15, 2026 at 9:36 AM
Hello Michael, The SPI use simple file sharing network to connect to the server. This error “Not connected to network with Q-up Navi. It inspects without a data output as a result of Q-up Navi.” means that the SPI cannot connect to the server. When you click "Yes" it will not send the data to Q-Up Navi and if click "No" it will try to reestablish the connection to server. The ping command simply confirms low level connection to the server, and it would not confirm if the SPI has the write permissions to the server. The simple way to check the server connection and write permission is to open file explorer and type the address of the server on the address bar: \\192.168.70.247 This will display the share folders on the server and the SPI should have Read/Write access to the share folder. If this displays a connection error then it is some network connection problem. Hope this help. Please let us know if you need assistance via remote assistance. Best Regards
C
CustomerCustomer reply | Apr 17, 2026 at 8:49 AM
Good morning, I would like to apologize for my delay in response. We’re having some additional odd behavior. The previous email you sent with instructions weren’t followed because I was informed by my team members that they restarted the machine and the QUP Navi error did not pop up again. So, I operated falsely under the belief that this situation had resolved itself. I discovered yesterday there still is a situation going on. So, when they attempt to have the SPI scan boards automatically it freezes up and we are forced to close the software. When they attempt to manually scan boards it freezes up and we are forced to close the software. The only function that doesn’t cause it to freeze and lock up is running the boards in pass through mode. I would like to have someone remote into our system and try to figure this out. Sincerely, [email] Michael Tufts SMT Manager Mobile [phone] Email [email] Web www.bgmeng.com Engineering / Manufacturing 14100 Simone Drive Shelby Twp., MI 48315 WARNING: The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination, or other use of, or taking any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer. This communication could contain technical data whose export is restricted by the Arms Export Control Act (Tile 22, U.S.C., 22401 et seq.) and the International Traffic and Arms Regulations. Such technical data may not be disclosed to foreign persons or otherwise exported without obtaining required U.S. Government export authorization. Violations of these export laws are subject to severe criminal penalties.
attachmentfreshdesk-inline-150158148502.png
OA
Omron Application EngineerOmron reply | Apr 17, 2026 at 8:59 AM
Hello Michael, Can you start teamviewer again? I will login and look.
C
CustomerCustomer reply | Apr 17, 2026 at 9:04 AM
1 294 436 492 5fftepym I’d appreciate a phone call as well so you can talk me through this issue. My management team upfront will have questions. [phone] Sincerely, [email] Michael Tufts SMT Manager Mobile [phone] Email [email] Web www.bgmeng.com Engineering / Manufacturing 14100 Simone Drive Shelby Twp., MI 48315 WARNING: The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any review, retransmission, dissemination, or other use of, or taking any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender and delete the material from any computer. This communication could contain technical data whose export is restricted by the Arms Export Control Act (Tile 22, U.S.C., 22401 et seq.) and the International Traffic and Arms Regulations. Such technical data may not be disclosed to foreign persons or otherwise exported without obtaining required U.S. Government export authorization. Violations of these export laws are subject to severe criminal penalties.
freshdesk-inline-150158151642.png
2 tiny or repeated images hidden.
OA
Omron Application EngineerOmron reply | Apr 17, 2026 at 9:37 AM
Hello Michael, Glad we were able to resolve the issue. Seems like the Q-up Navi server IP changed, and was changed back to original IP. I believe this caused windows credentials issues. We have confirmed that the machine is back in working order. Thanks!
OA
Omron Application EngineerOmron reply | Apr 17, 2026 at 11:29 AM
No sanitized conversation text indexed.
C
CustomerCustomer reply | Apr 17, 2026 at 12:08 PM
Private
No sanitized conversation text indexed.
AI
Omron Application Engineer
Ticket copilot
Connecting
Ticket#1744943 SPI Machine Not Connecting to QUPNAVI